Difference: TrbNetOnewire (r2 vs. r1)

Trb-Net Onewire interface

This entity provides a very simple 1-wire master to read out the id of a 1-wire device. It does not support busses with more than one device device. and does not check if the device is really present. Other commands than READ ROM are not supported.

The entity provides one tristate port to connect to the one wire bus. The data is output on a data port along with an address (counting from 1 to 4, according to TrbNetAddresses) and a write signal. This output port will be connected to TrbNetRegIOand . not directly to TrbNetAddresses, since we may want to be able to read out this ram from another point.

The temperature of the sensor is also read out and provided on a 12 bit port in the sensors native data format (1/16th degree celsius in case of an DS18B20)

-- JanMichel - 03 Apr 2008

View topic | View difference side by side | History: r2 < r1 | More topic actions
 
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Hades Wiki? Send feedback
Imprint (in German)
Privacy Policy (in German)