Difference: TestsMDCII (1 vs. 4)

Revision 4
29 Mar 2011 - Main.GosiaSudol
Line: 1 to 1
 
META TOPICPARENT name="DataTestLogBook"

test of MDC II performed day: 29.03.2011

Line: 10 to 10
 

We can see some kind of pattern, which is repeated in all sectors, where some of the TDCs do not
deliver all 6 data words. This should be check if this is correct.
Changed:
<
<
In sector 3, the motherboard 6 is only missing after a power cycle!
>
>
In sector 3, the motherboard 6 is only missing after a power cycle! (not visible here, since file was taken before power cycle)
 

One TDC is missing in all 6 sectors

Revision 3
29 Mar 2011 - Main.GosiaSudol
Line: 1 to 1
 
META TOPICPARENT name="DataTestLogBook"

test of MDC II performed day: 29.03.2011

Line: 14 to 14
 

One TDC is missing in all 6 sectors

Added:
>
>
mdc II, calibration
 

-- Johannes and Gosia
Deleted:
<
<
mdc II, calibration
 

META FILEATTACHMENT attr="" comment="mdc II, calibration" date="1301415442" name="mdcII_cal.gif" path="mdcII_cal.gif" size="55955" user="GosiaSudol" version="1.1"
Added:
>
>
META FILEATTACHMENT attr="" comment="mdc II, calibration" date="1301423197" name="mdcII_cal1.gif" path="mdcII_cal1.gif" size="52580" user="GosiaSudol" version="1.1"
Revision 2
29 Mar 2011 - Main.JohannesSiebenson
Line: 1 to 1
 
META TOPICPARENT name="DataTestLogBook"

test of MDC II performed day: 29.03.2011

Deleted:
<
<

blablabla

test of MDC II performed day: 29.03.2011

  We have collected only calibration events, by setting: trigger type 9 on and pulser 10Hz.
Threshold has been set to 40 for all planes.
Changed:
<
<
Following picture is showing typical patern MBO vs. TDC for MDC IV (sector 2 is not connected).
>
>
The following pictures are showing typical patterns (MBO vs. TDC) for MDC II.
 

In this plot we only get a entry in case that TDC delivered 6 data words.

We can see some kind of pattern, which is repeated in all sectors, where some of the TDCs do not
deliver all 6 data words. This should be check if this is correct.
Added:
>
>
In sector 3, the motherboard 6 is only missing after a power cycle!
 
Changed:
<
<
In addition we are missing some data words in sector 4 MBO 14.
>
>
One TDC is missing in all 6 sectors
 

-- Johannes and Gosia
 