Trb-Net Onewire interface

Changed:
<
<
This entity provides a very simple 1-wire master to read out the id of a 1-wire device. It does not support busses with more than one device and does not check if the device is really present. Other commands than READ ROM are not supported.
>
>
This entity provides a very simple 1-wire master to read out the id of a 1-wire device. It does not support busses with more than one device.

The entity provides one tristate port to connect to the one wire bus. The data is output on a data port along with an address (counting from 1 to 4, according to TrbNetAddresses) and a write signal. This output port will be connected to TrbNetRegIO.

The temperature of the sensor is also read out and provided on a 12 bit port in the sensors native data format (1/16th degree celsius in case of an DS18B20)
 
Deleted:
<
<
The entity provides one tristate port to connect to the one wire bus. The data is output on a data port along with an address (counting from 1 to 4, according to TrbNetAddresses) and a write signal. This output port will be connected to TrbNetRegIO and not directly to TrbNetAddresses, since we may want to be able to read out this ram from another point.
 

 