Difference: WebHome (1 vs. 17)

Revision 17
30 Jan 2015 - Main.JochenMarkert
Line: 1 to 1
 

Hodoscope detectors

Three pieces of Hodoscope detectors for beam position monitoring are available. Two of them are identical with scintillator rod dimensions 100 x 10 x 5 mm, the third one has smaller rods (100 x 6.5 x 6.5 mm). All three detectors show significant light attenuation inside the scintillators and had to be repaired in Optical laboratories of the Charles University in Prague, Czech Republic.
Line: 23 to 23
 

High Voltage for PMTs

Changed:
<
<
How to set HV
>
>
How to set HV
 

HV values on Hodoscope nr.2: HV_for_hodoscope.pdf

Revision 16
30 Sep 2014 - Main.OndrejSvoboda
Line: 1 to 1
 

Hodoscope detectors

Three pieces of Hodoscope detectors for beam position monitoring are available. Two of them are identical with scintillator rod dimensions 100 x 10 x 5 mm, the third one has smaller rods (100 x 6.5 x 6.5 mm). All three detectors show significant light attenuation inside the scintillators and had to be repaired in Optical laboratories of the Charles University in Prague, Czech Republic.
Line: 9 to 9
 

Photomultipliers datasheet: Photomultiplier_tube_R3478.pdf
Added:
>
>

Hodoscope drawings

created in SimpleGeo (http://theis.web.cern.ch/theis/simplegeo/)
  Hodoscope drawings ppt: Hodoscope_drawings.pptx

Hodoscope drawings pdf: Hodoscope_drawings.pdf
Added:
>
>
Source file Hodoscope_drawings_source.dat

Material file materials.db
 

High Voltage for PMTs

How to set HV
Line: 114 to 122
 
META FILEATTACHMENT attachment="after_repair.pdf" attr="" comment="90Sr measurement of hodoscope nr. 2 after repair" date="1399361149" name="after_repair.pdf" path="after_repair.pdf" size="266218" user="OndrejSvoboda" version="1"
META FILEATTACHMENT attachment="Lookup_table_start_cathegory.txt" attr="" comment="Look-up table for start cathegory" date="1399368271" name="Lookup_table_start_cathegory.txt" path="Lookup_table_start_cathegory.txt" size="49781" user="OndrejSvoboda" version="1"
META FILEATTACHMENT attachment="calibpar_notshifted.txt" attr="" comment="LookUp plus CalPars (before shift)" date="1408476824" name="calibpar_notshifted.txt" path="calibpar_notshifted.txt" size="6229" user="LukasChlad" version="1"
Added:
>
>
META FILEATTACHMENT attachment="Hodoscope_drawings.pdf" attr="" comment="Hodoscope drawings pdf" date="1412058799" name="Hodoscope_drawings.pdf" path="Hodoscope_drawings.pdf" size="1346601" user="OndrejSvoboda" version="1"
META FILEATTACHMENT attachment="Hodoscope_drawings.pptx" attr="" comment="Hodoscope drawings pptx" date="1412058911" name="Hodoscope_drawings.pptx" path="Hodoscope_drawings.pptx" size="3890663" user="OndrejSvoboda" version="1"
META FILEATTACHMENT attachment="Hodoscope.dat" attr="" comment="Hodoscope drawings source file" date="1412059796" name="Hodoscope.dat" path="Hodoscope.dat" size="338944" user="OndrejSvoboda" version="1"
META FILEATTACHMENT attachment="materials.db" attr="" comment="Hodoscope drawings material file" date="1412059904" name="materials.db" path="materials.db" size="3108" user="OndrejSvoboda" version="1"
Revision 15
15 Sep 2014 - Main.OndrejSvoboda
Line: 1 to 1
 

Hodoscope detectors

Three pieces of Hodoscope detectors for beam position monitoring are available. Two of them are identical with scintillator rod dimensions 100 x 10 x 5 mm, the third one has smaller rods (100 x 6.5 x 6.5 mm). All three detectors show significant light attenuation inside the scintillators and had to be repaired in Optical laboratories of the Charles University in Prague, Czech Republic.
Line: 9 to 9
 

Photomultipliers datasheet: Photomultiplier_tube_R3478.pdf
Added:
>
>
Hodoscope drawings ppt: Hodoscope_drawings.pptx

Hodoscope drawings pdf: Hodoscope_drawings.pdf
 

High Voltage for PMTs

How to set HV
Revision 14
19 Aug 2014 - Main.OndrejSvoboda
Line: 1 to 1
 

Hodoscope detectors

Three pieces of Hodoscope detectors for beam position monitoring are available. Two of them are identical with scintillator rod dimensions 100 x 10 x 5 mm, the third one has smaller rods (100 x 6.5 x 6.5 mm). All three detectors show significant light attenuation inside the scintillators and had to be repaired in Optical laboratories of the Charles University in Prague, Czech Republic.
Line: 65 to 65
 

How to analyze the data (may 14 test):
Changed:
<
<
QA was moved to hades-qa@lxhadeb06.gsi.de (6$......-qa)
>
>
QA was moved to hadestof@lxhadeb06.gsi.de
 

0.) go to folder /analysis/tof/May14
Revision 13
19 Aug 2014 - Main.LukasChlad
Line: 1 to 1
 

Hodoscope detectors

Three pieces of Hodoscope detectors for beam position monitoring are available. Two of them are identical with scintillator rod dimensions 100 x 10 x 5 mm, the third one has smaller rods (100 x 6.5 x 6.5 mm). All three detectors show significant light attenuation inside the scintillators and had to be repaired in Optical laboratories of the Charles University in Prague, Czech Republic.
Line: 59 to 59
 

or from WiFi: http://cerberus.x-matter.uni-frankfurt.de:3060/mon
Added:
>
>
OR via SOCKS proxy setting:

1. open a ssh connection and activate 'dynamic port forwarding'
ssh -D 1080 USERNAME@lxi001.gsi.de

2. Setup SOCKS proxy in Firefox
Edit->Preferences->Advanced
open tab 'Network'
click on Connection 'Settings...'
activate 'Manual Proxy Configuration'
setup:
SOCKS Host: localhost Port: 1080
(ensure that all other Proxy fields are blank (or 0))
  How to analyze the data (may 14 test):

QA was moved to hades-qa@lxhadeb06.gsi.de (6$......-qa)
Line: 81 to 85
 

exchange of 2 modified Padiwas for lower rods
Changed:
<
<
8->4
>
>
8->3
 

1->16
Added:
>
>
LookUp table and CalParameters for START and HODO: calibpar_notshifted.txt
 

HODO Web Utilities

Line: 103 to 109
 
META FILEATTACHMENT attachment="hodoscope.jpg" attr="" comment="hodoscope layout" date="1399359062" name="hodoscope.jpg" path="hodoscope.jpg" size="290379" user="OndrejSvoboda" version="1"
META FILEATTACHMENT attachment="after_repair.pdf" attr="" comment="90Sr measurement of hodoscope nr. 2 after repair" date="1399361149" name="after_repair.pdf" path="after_repair.pdf" size="266218" user="OndrejSvoboda" version="1"
META FILEATTACHMENT attachment="Lookup_table_start_cathegory.txt" attr="" comment="Look-up table for start cathegory" date="1399368271" name="Lookup_table_start_cathegory.txt" path="Lookup_table_start_cathegory.txt" size="49781" user="OndrejSvoboda" version="1"
Added:
>
>
META FILEATTACHMENT attachment="calibpar_notshifted.txt" attr="" comment="LookUp plus CalPars (before shift)" date="1408476824" name="calibpar_notshifted.txt" path="calibpar_notshifted.txt" size="6229" user="LukasChlad" version="1"
Revision 12
18 Aug 2014 - Main.LukasChlad
Line: 1 to 1
 

Hodoscope detectors

Three pieces of Hodoscope detectors for beam position monitoring are available. Two of them are identical with scintillator rod dimensions 100 x 10 x 5 mm, the third one has smaller rods (100 x 6.5 x 6.5 mm). All three detectors show significant light attenuation inside the scintillators and had to be repaired in Optical laboratories of the Charles University in Prague, Czech Republic.
Line: 83 to 83
 

8->4
Changed:
<
<
4->16
>
>
1->16
 

HODO Web Utilities

Revision 11
15 Aug 2014 - Main.OndrejSvoboda
Line: 1 to 1
 

Hodoscope detectors

Three pieces of Hodoscope detectors for beam position monitoring are available. Two of them are identical with scintillator rod dimensions 100 x 10 x 5 mm, the third one has smaller rods (100 x 6.5 x 6.5 mm). All three detectors show significant light attenuation inside the scintillators and had to be repaired in Optical laboratories of the Charles University in Prague, Czech Republic.
Line: 55 to 55
 

open web browser from any machine in GSI network: hades33/mon/
Added:
>
>
or from outside: http://cerberus.x-matter.uni-frankfurt.de:8888/mon

or from WiFi: http://cerberus.x-matter.uni-frankfurt.de:3060/mon
  How to analyze the data (may 14 test):

QA was moved to hades-qa@lxhadeb06.gsi.de (6$......-qa)
Revision 10
06 Aug 2014 - Main.AdrianRost
Line: 1 to 1
 

Hodoscope detectors

Three pieces of Hodoscope detectors for beam position monitoring are available. Two of them are identical with scintillator rod dimensions 100 x 10 x 5 mm, the third one has smaller rods (100 x 6.5 x 6.5 mm). All three detectors show significant light attenuation inside the scintillators and had to be repaired in Optical laboratories of the Charles University in Prague, Czech Republic.
Line: 71 to 71
 

3.) use analysis macro from /makeDST_ilse to analyse the files (./analysisDST name_of_the_file_from_step_1 number_of_events)
Added:
>
>

Beamtime info

August14

exchange of 2 modified Padiwas for lower rods

8->4

4->16
 

HODO Web Utilities

Revision 9
27 Jun 2014 - Main.AdrianRost
Line: 1 to 1
 

Hodoscope detectors

Three pieces of Hodoscope detectors for beam position monitoring are available. Two of them are identical with scintillator rod dimensions 100 x 10 x 5 mm, the third one has smaller rods (100 x 6.5 x 6.5 mm). All three detectors show significant light attenuation inside the scintillators and had to be repaired in Optical laboratories of the Charles University in Prague, Czech Republic.
Line: 14 to 14
  How to set HV

HV values on Hodoscope nr.2: HV_for_hodoscope.pdf
Added:
>
>

VNCs

 
Added:
>
>
vncviewer hadesdaq01:1 is main DAQ VNC

vncviewer hadesdaq01:2 is used for HODO/START

 

Thresholds on PaDiWa Amps

Setting the thresholds on PaDiWa front-end boards Thresholds
Revision 8
18 Jun 2014 - Main.OndrejSvoboda
Line: 1 to 1
 

Hodoscope detectors

Three pieces of Hodoscope detectors for beam position monitoring are available. Two of them are identical with scintillator rod dimensions 100 x 10 x 5 mm, the third one has smaller rods (100 x 6.5 x 6.5 mm). All three detectors show significant light attenuation inside the scintillators and had to be repaired in Optical laboratories of the Charles University in Prague, Czech Republic.
Revision 7
18 Jun 2014 - Main.OndrejSvoboda
Line: 1 to 1
 

Hodoscope detectors

Three pieces of Hodoscope detectors for beam position monitoring are available. Two of them are identical with scintillator rod dimensions 100 x 10 x 5 mm, the third one has smaller rods (100 x 6.5 x 6.5 mm). All three detectors show significant light attenuation inside the scintillators and had to be repaired in Optical laboratories of the Charles University in Prague, Czech Republic.
Line: 19 to 19
 

Setting the thresholds on PaDiWa front-end boards Thresholds
Added:
>
>
TDC calibration of TRB3TRB3calibration
  Look-up table (24. 4. 2014): Lookup_table_start_category.pdf

Attenuation before repair

Revision 6
06 May 2014 - Main.OndrejSvoboda
Line: 1 to 1
 

Hodoscope detectors

Three pieces of Hodoscope detectors for beam position monitoring are available. Two of them are identical with scintillator rod dimensions 100 x 10 x 5 mm, the third one has smaller rods (100 x 6.5 x 6.5 mm). All three detectors show significant light attenuation inside the scintillators and had to be repaired in Optical laboratories of the Charles University in Prague, Czech Republic.
Line: 19 to 19
 

Setting the thresholds on PaDiWa front-end boards Thresholds
Changed:
<
<
Look-up table (24. 4. 2014): Lookup_table_start_cathegory.txt
>
>
Look-up table (24. 4. 2014): Lookup_table_start_category.pdf
 

Attenuation before repair

Revision 5
06 May 2014 - Main.OndrejSvoboda
Line: 1 to 1
 

Hodoscope detectors

Three pieces of Hodoscope detectors for beam position monitoring are available. Two of them are identical with scintillator rod dimensions 100 x 10 x 5 mm, the third one has smaller rods (100 x 6.5 x 6.5 mm). All three detectors show significant light attenuation inside the scintillators and had to be repaired in Optical laboratories of the Charles University in Prague, Czech Republic.
Added:
>
>
Hodoscope
  Hodoscope publication in NIM: Pion_beam-hodoscope.pdf

Photomultipliers datasheet: Photomultiplier_tube_R3478.pdf
Line: 13 to 15
 

HV values on Hodoscope nr.2: HV_for_hodoscope.pdf
Added:
>
>

Thresholds on PaDiWa Amps

Setting the thresholds on PaDiWa front-end boards Thresholds

Look-up table (24. 4. 2014): Lookup_table_start_cathegory.txt
 

Attenuation before repair

Added:
>
>
Attenutaion length before repair was 4 - 7 cm depanding on the rod and method of measurement (cosmic muons, gamma or beta radiation).
  Hodoscope nr.3 - measurement with 90Sr radioactive source: Hodoskop3_attenuation.pdf

After repair

Added:
>
>
Attenuation length after exchange of scintillator rods is cca 24 cm.

Short report about attenuation measurement after repair: after_repair.pdf
 

Beam results

Pulse amplitudes on protons measured with osciloscope:
Line: 29 to 43
 

Heat map Profile
Added:
>
>
QA over web browser:

open web browser from any machine in GSI network: hades33/mon/

How to analyze the data (may 14 test):

QA was moved to hades-qa@lxhadeb06.gsi.de (6$......-qa)

0.) go to folder /analysis/tof/May14

1.) to find last 20 hld files type: zsh ls -ltr /store/**/*.hld(.om[0,20]L+33)

2.) run defall.sh placed in the /makeDST/ folder

3.) use analysis macro from /makeDST_ilse to analyse the files (./analysisDST name_of_the_file_from_step_1 number_of_events)
 

HODO Web Utilities

Line: 44 to 76
 
META FILEATTACHMENT attachment="Hodoskop3_attenuation.pdf" attr="" comment="Attenuation measurement with Hodoscope nr.3 and 90Sr source" date="1399292609" name="Hodoskop3_attenuation.pdf" path="Hodoskop3_attenuation.pdf" size="544104" user="OndrejSvoboda" version="1"
META FILEATTACHMENT attachment="hodoscope_heatmap.jpg" attr="" comment="Hodoscope heatmap with well focused beam" date="1399293101" name="hodoscope_heatmap.jpg" path="hodoscope_heatmap.jpg" size="7205" user="OndrejSvoboda" version="1"
META FILEATTACHMENT attachment="hodoscope_profile.jpg" attr="" comment="Beam profile in Y axis seen in Hodoscope" date="1399293464" name="hodoscope_profile.jpg" path="hodoscope_profile.jpg" size="3348" user="OndrejSvoboda" version="1"
Added:
>
>
META FILEATTACHMENT attachment="hodoscope.jpg" attr="" comment="hodoscope layout" date="1399359062" name="hodoscope.jpg" path="hodoscope.jpg" size="290379" user="OndrejSvoboda" version="1"
META FILEATTACHMENT attachment="after_repair.pdf" attr="" comment="90Sr measurement of hodoscope nr. 2 after repair" date="1399361149" name="after_repair.pdf" path="after_repair.pdf" size="266218" user="OndrejSvoboda" version="1"
META FILEATTACHMENT attachment="Lookup_table_start_cathegory.txt" attr="" comment="Look-up table for start cathegory" date="1399368271" name="Lookup_table_start_cathegory.txt" path="Lookup_table_start_cathegory.txt" size="49781" user="OndrejSvoboda" version="1"
Revision 4
05 May 2014 - Main.OndrejSvoboda
Line: 1 to 1
 

Hodoscope detectors

Added:
>
>
Three pieces of Hodoscope detectors for beam position monitoring are available. Two of them are identical with scintillator rod dimensions 100 x 10 x 5 mm, the third one has smaller rods (100 x 6.5 x 6.5 mm). All three detectors show significant light attenuation inside the scintillators and had to be repaired in Optical laboratories of the Charles University in Prague, Czech Republic.
  Hodoscope publication in NIM: Pion_beam-hodoscope.pdf

Photomultipliers datasheet: Photomultiplier_tube_R3478.pdf
Line: 23 to 25
 

Pulse amplitudes
Changed:
<
<
"Heat map" with well focused beam:                        Beam profile on hodoscope (Y axis):
>
>
"Heat map" with well focused beam: Beam profile on hodoscope (Y axis):
 

Heat map Profile
Revision 3
05 May 2014 - Main.OndrejSvoboda
Line: 1 to 1
 

Hodoscope detectors

Hodoscope publication in NIM: Pion_beam-hodoscope.pdf
Line: 11 to 11
 

HV values on Hodoscope nr.2: HV_for_hodoscope.pdf
Changed:
<
<
"Heat map" with well focused beam Heat map
>
>

Attenuation before repair

Hodoscope nr.3 - measurement with 90Sr radioactive source: Hodoskop3_attenuation.pdf

After repair

Beam results

Pulse amplitudes on protons measured with osciloscope:

Pulse amplitudes

"Heat map" with well focused beam:                        Beam profile on hodoscope (Y axis):

Heat map Profile
 

HODO Web Utilities

Line: 25 to 38
 
META FILEATTACHMENT attachment="Pion_beam-hodoscope.pdf" attr="" comment="Design and commissioning of the GSI pion beam - hodoscope description" date="1399285822" name="Pion_beam-hodoscope.pdf" path="Pion_beam-hodoscope.pdf" size="450574" user="OndrejSvoboda" version="1"
META FILEATTACHMENT attachment="Photomultiplier_tube_R3478.pdf" attr="" comment="Photomultiplier tube from hodoscope" date="1399286066" name="Photomultiplier_tube_R3478.pdf" path="Photomultiplier_tube_R3478.pdf" size="220888" user="OndrejSvoboda" version="1"
META FILEATTACHMENT attachment="HV_for_hodoscope.pdf" attr="" comment="High Voltage for Hodoscope nr.2" date="1399286611" name="HV_for_hodoscope.pdf" path="HV_for_hodoscope.pdf" size="257096" user="OndrejSvoboda" version="1"
Added:
>
>
META FILEATTACHMENT attachment="hodo_pulse_amplitude.jpg" attr="" comment="Pulse amplitudes from Hodoscope nr.2 stripe 0, protons 2 GeV" date="1399291407" name="hodo_pulse_amplitude.jpg" path="hodo_pulse_amplitude.jpg" size="148622" user="OndrejSvoboda" version="2"
META FILEATTACHMENT attachment="Hodoskop3_attenuation.pdf" attr="" comment="Attenuation measurement with Hodoscope nr.3 and 90Sr source" date="1399292609" name="Hodoskop3_attenuation.pdf" path="Hodoskop3_attenuation.pdf" size="544104" user="OndrejSvoboda" version="1"
META FILEATTACHMENT attachment="hodoscope_heatmap.jpg" attr="" comment="Hodoscope heatmap with well focused beam" date="1399293101" name="hodoscope_heatmap.jpg" path="hodoscope_heatmap.jpg" size="7205" user="OndrejSvoboda" version="1"
META FILEATTACHMENT attachment="hodoscope_profile.jpg" attr="" comment="Beam profile in Y axis seen in Hodoscope" date="1399293464" name="hodoscope_profile.jpg" path="hodoscope_profile.jpg" size="3348" user="OndrejSvoboda" version="1"
Revision 2
05 May 2014 - Main.OndrejSvoboda
Line: 1 to 1
Changed:
<
<

Welcome to the HODO web

Home of HODO detector

Available Information

  • ...
  • ...
  • ...
>
>

Hodoscope detectors

Hodoscope publication in NIM: Pion_beam-hodoscope.pdf

Photomultipliers datasheet: Photomultiplier_tube_R3478.pdf

High Voltage for PMTs

How to set HV

HV values on Hodoscope nr.2: HV_for_hodoscope.pdf

"Heat map" with well focused beam Heat map
 

HODO Web Utilities

Line: 14 to 21
 
Added:
>
>

META FILEATTACHMENT attachment="Pion_beam-hodoscope.pdf" attr="" comment="Design and commissioning of the GSI pion beam - hodoscope description" date="1399285822" name="Pion_beam-hodoscope.pdf" path="Pion_beam-hodoscope.pdf" size="450574" user="OndrejSvoboda" version="1"
META FILEATTACHMENT attachment="Photomultiplier_tube_R3478.pdf" attr="" comment="Photomultiplier tube from hodoscope" date="1399286066" name="Photomultiplier_tube_R3478.pdf" path="Photomultiplier_tube_R3478.pdf" size="220888" user="OndrejSvoboda" version="1"
META FILEATTACHMENT attachment="HV_for_hodoscope.pdf" attr="" comment="High Voltage for Hodoscope nr.2" date="1399286611" name="HV_for_hodoscope.pdf" path="HV_for_hodoscope.pdf" size="257096" user="OndrejSvoboda" version="1"
 
This site is powered by FoswikiCopyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Hades Wiki? Send feedback
Imprint (in German)
Privacy Policy (in German)