MarekPalka - 16 Nov 2006
On the picture below is presented crosstalk measured on 2 channels.
On one channel is pulse which is about 55ns wide. Disturbing channel is 10 ns long. Delay is value on generator, but disturbing channel cables were 30 cm longer so its makes about 1ns delay in addition. Plot will be shifted to the right.
These are preliminary results. We have to make this measurements with lvds adapter to avoid signal reflections in cable.
- cross talk:
- time relations in crosstalk measurements:
--
KrzysztofKorcyl - 17 Nov 2006
COMMENT: It may be interesting to see coincidence of RISING edge of the measured pulse with FALLING edge of the disturbing pulse. Could you therefore extend the "delay" to -10 ns at least (or better to -15 ns) with the same width of the disturbing pulse?.
Yes I will do this - but unfortunately we don't have now generator... (next measurements will be possible in next month).