DAQ Upgrade - Installation of TRB, AddOn, Network...
Trigger Distribution
- RPC: One PECL->LVDS converter on each sector
- Shower: Same distributor board as RPC
- TOF: One PECL->LVDS distributor on each sector
- MDC 3/4: Same as TOF distributor
- MDC 1/2: One PECL->LVDS distributor on two sectors. Then LVDS connection to FanPW on each sector
- RICH: own trigger distribution, four LVDS lines from CTS, own LVDS->LVDS distributor board
- Start, Veto: Connected to TOF-Distributor to have the same jitter on Start and TOF
- Wall: One PECL-> LVDS distributor
Total: 6 RPC/Shower, 2 MDC12, 6 TOF/MDC34, 1 Wall -> 15 PECL-LVDS-Boards needed;
TrbNet Hubs
Detector |
Hubs |
Setup |
Position |
MDC34 |
1 |
no Gbe |
front right corner of mainframe |
MDC12 |
1 |
no Gbe |
under right platform, next to MDC power supplies |
RPC |
2 |
no Gbe |
rear right corner of mainframe |
TOF |
1 |
no Gbe |
front right corner of mainframe |
Shower |
1 |
no Gbe |
rear right corner of mainframe |
RICH |
3 |
Gbe |
under right platform, next to MDC power supplies |
CTS / Others |
1 |
maybe Gbe |
in old trigger rack |
Total: 10 TRB-Hub2 boards
TRBs
Detector |
Amount |
Configuration |
RPC |
24 |
with TDC |
TOF |
7 |
with TDC |
Shower |
0 |
AddOn on RPC-TRB |
MDC |
0 |
New MDC Concentratos is a stand-alone board |
RICH |
0 |
|
Hubs |
10 |
power supply & Etrax only |
CTS |
2 |
One board CTS, one for slow control |
Forward Wall |
3 |
with TDC |
Start/Veto |
1 |
with TDC |
Network Switches
Name |
Detector |
Datarate |
Downlinks |
Uplinks |
Position |
HADSW01 |
Shower & RPC 1,2,3 |
45 |
6x Shower, 1x RPC |
05P-18 |
rear right corner, new 16/4port switch |
HADSW02 |
Shower & RPC 4,5,6 |
45 |
6x Shower, 1x RPC |
05P-17 |
rear right corner, new 16/4port switch |
HADSW03 |
MDC12 1,2,3 |
60 |
3x MDC |
01C-06 |
under right platform, 12/12port switch |
HADSW04 |
MDC12 4,5,6 |
60 |
3x MDC |
01C-03 |
under right platform, 12/12port switch |
HADSW05 |
MDC34 2,3,4, TOF 1-4 |
60 |
3x MDC, 4x TOF 1-4 |
1 |
front right corner, new 16/4port switch |
HADSW06 |
MDC34 1,5,6 TOF 5-X |
60 |
3x MDC, 3x TOF 5,6,X |
1 |
front right corner, new 16/4port switch |
--- |
RICH |
100 |
3x RICH GbE |
01C-05, 01C-07, 01C-04 |
under right platform, no switch, only media converters |
HADSW07 |
Foward Wall |
30 |
1x FW GbE, 4x TRB |
01C-08 |
|
HADSW08 |
Shower 5,6 |
100 |
2x Shower |
05Q-20 |
table, rear right corner |
HADSW09 |
Shower 2,3 |
100 |
2x Shower |
05Q-19 |
table, rear right corner |
Switch 7 |
MDC LV et.al. |
0 |
8x MDC Power Supplies |
01C-01 |
above MDC LV power supplies |
Switch 8 |
CTS |
5 |
CTS, other boards on CTS stack |
1 |
on CTS stack |
Switch 9 |
RICH |
0 |
4x Rich / MDC12 SCtrl |
via Switch 7 |
RICH TRB stack |
Switch 10 - 15 |
RPC / Shower |
0 |
4x RPC TRB, 1x Hadcon |
via HADSW01/02 |
on each sector |
Port Usage
HADSW01 (RPC/Shower 1,2,3) (192.168.100.29)
- Port 1: RPC/Shower sector 1
- Port 2: RPC/Shower sector 2
- Port 3: RPC/Shower sector 3
- Port 9: RPC Hub sector 1,2,3
- Port 12: Uplink, port on wall 05P-18
- Port A: Shower sector 1
- Port B: Shower sector 2 (moved to HADSW09)
- Port C: Shower sector 3 (moved to HADSW09)
HADSW02 (RPC/Shower 4,5,6) (192.168.100.30)
- Port 1: RPC/Shower sector 4
- Port 2: RPC/Shower sector 5
- Port 3: RPC/Shower sector 6
- Port 9: RPC Hub sector 4,5,6
- Port 10: Shower Hub
- Port 12: Uplink, port on wall 05P-17
- Port A: Shower sector 4
- Port B: Shower sector 5 (moved to HADSW08)
- Port C: Shower sector 6 (moved to HADSW08)
HADSW03 (MDC 1/2 1,2,3)
- Port 1: MDC1/2 sector 1
- Port 2: MDC1/2 sector 2
- Port 3: MDC1/2 sector 3
- Port 12: Uplink, port 6 on patch panel, 01C-06
HADSW04 (MDC 1/2 4,5,6)
- Port 1: MDC1/2 sector 4
- Port 2: MDC1/2 sector 5
- Port 3: MDC1/2 sector 6
- Port 12: Uplink, port 3 on patch panel, 01C-03
HADSW05 (MDC 3/4 1,2,3)
- Port A: MDC1/2 sector 1
- Port B: MDC1/2 sector 2
- Port C: MDC1/2 sector 3
- Port 1: TOF 1
- Port 2: TOF 2
- Port 3: TOF 3
- Port 4: TOF 4
- Port 8: Mainframe left side
- Port 9: TOF Hub
- Port 10: MDC 3/4 Hub
- Port 12: Uplink, 05Q-18
HADSW06 (MDC 3/4 4,5,6)
- Port A: MDC1/2 sector 4
- Port B: MDC1/2 sector 5
- Port C: MDC1/2 sector 6
- Port 1: TOF 5
- Port 2: TOF 6
- Port 3: TOF X (extra board)
- Port 12: Uplink, 05Q-16
HADSW07 (Forward Wall)
- Port A: Forward Wall Hub
- Port 1: Forward Wall TRB 1
- Port 2: Forward Wall TRB 2
- Port 3: Forward Wall TRB 3
- Port 5: Hub TRB
- Port 8: High Voltage 1
- Port 9: haepc06 (expert power control)
- Port 12: Uplink, 01C-08
HADSW08 (Shower 5,6) (192.168.100.24)
- Port A: Shower 5
- Port B: Shower 6
HADSW09 (Shower 2,3) (192.168.100.23)
- Port A: Shower 2
- Port B: Shower 3
Switch 7 (Power Supplies)
- Ports 1 - 11: power supplies
- Port 12: MDC1/2, RICH slow control
- Port 24: Uplink, port 1 on patch panel via white switch
TrbNet Hubs
Physical connections. Ports 5 to 16 are mapped to Port 1 to 12 internally.
Central Hub
- Port 20: CTS
- Port 18: SCS
- Port 5: RPC sec. 1 2 3
- Port 6: RPC sec. 4 5 6
- Port 7: MDC 1/2
- Port 8: MDC 3/4
- Port 9: Forward Wall
- Port 10: TOF
- Port 11: Shower
- Port 12: RICH 1/2
- Port 13: RICH 3/4
- Port 14: RICH 5/6
RICH 1,2
- Port 20: Uplink
- Port 17: GBE
- Port 5 - 9: RICH sector 1, segments 0 - 4
- Port 10 - 14: RICH sector 2, segments 0 - 4
RICH 3,4
- Port 20: Uplink
- Port 17: GBE
- Port 5 - 9: RICH sector 3, segments 0 - 4
- Port 10 - 14: RICH sector 4, segments 0 - 4
RICH 5,6
- Port 20: Uplink
- Port 17: GBE
- Port 5 - 9: RICH sector 5, segments 0 - 4
- Port 10 - 14: RICH sector 6, segments 0 - 4
MDC 1,2
- Port 20: Uplink
- Port 5 - 10: MDC plane 1/2, sectors 1 to 6
MDC 3,4
- Port 20: Uplink
- Port 5 - 10: MDC plane 3/4, sectors 1 to 6
TOF
- Port 20: Uplink
- Port 17: GBE
- Port 5 - 10: TOF sectors 1 to 6
- Port 11: TOF extra board
RPC 1,2,3
- Port 20: Uplink
- Port 17: GBE
- Port 5 - 8: RPC sector 1, segments 0 - 3
- Port 9 - 12: RPC sector 2, segments 0 - 3
- Port 13 - 16: RPC sector 3, segments 0 - 3
RPC 4,5,6
- Port 20: Uplink
- Port 17: GBE
- Port 5 - 8: RPC sector 4, segments 0 - 3
- Port 9 - 12: RPC sector 5, segments 0 - 3
- Port 13 - 16: RPC sector 6, segments 0 - 3
Shower
- Port 20: Uplink
- Port 5: Shower sector 6
- Port 6: Shower sector 5
- Port 7: Shower sector 4
- Port 8: Shower sector 3
- Port 9: Shower sector 2
- Port 10: Shower sector 1
Forward Wall
- Port 20: Uplink
- Port 17: GBE
- Port 5 - 7: Forward Wall TRB 1 - 3
Position of TRB, AddOns, Switches
Here is the list of installations needed, ordered by location. "Lvln" refers to the level in the stack of boards.
- Behind RPC detector for each sector (height: 6 6 6 12 12)
- Lvl1 : Ethernet switch (4x TRB, 1x uplink), 48V distribution, Trigger distribution
- Lvl2 : TRB RPC part3
- Lvl3 : TRB RPC part2
- Lvl4 : TRB RPC part1, Shower AddOn
- Lvl5 : TRB RPC part0, Baseline restorer
- Rear right corner of mainframe (height: 6 6 6 6)
- Lvl1 : 48V distributor
- Lvl2 : RPC hub 1 (sector 1,2,3)
- Lvl3 : RPC hub 2 (sector 4,5,6)
- Lvl4 : Shower hub (all sectors)
- Optical switches (6x Shower, 6x ethernet switch, 3x Hub slow control, 2x uplink)
- Front left corner of mainframe (height: 6 6 6 6)
- Lvl1 : Ethernet switch, 48V distribution
- Lvl2 : MDCAddOn sector 1
- Lvl3 : MDCAddOn sector 6
- Lvl4 : MDCAddOn sector 5
- Front right corner of mainframe (height: 6 6 6 / 6 6 6)
- Lvl1.0 : 48V distribution
- Lvl1.1 : MDCAddOn sector 2
- Lvl1.2 : MDCAddOn sector 3
- Lvl1.3 : MDCAddOn sector 4
- Lvl2.1 : Ethernet switch, trigger distributor (TOF)
- Lvl2.2 : MDC3/4 Hub
- Lvl2.3 : TOF Hub
- Optical switch for MDC3/4
- Beside right platform, right of RICH / MDC 1/2 (height: 6 6 6 6 / 6 6 6 6 / 6 6 6 6)
- Lvl1.1 : MDCAddOn sector 1
- Lvl1.2 : MDCAddOn sector 5
- Lvl1.3 : MDCAddOn sector 6
- Lvl1.4 : MDC Hub
- Lvl2.1 : MDCAddOn sector 2
- Lvl2.2 : MDCAddOn sector 3
- Lvl2.3 : MDCAddOn sector 4
- Lvl2.4 : MDC1/2 Hub
- Lvl3.1 : Ethernet switch, 48V distribution
- Lvl3.2 : RICH hub sector 1,2
- Lvl3.3 : RICH hub sector 3,4
- Lvl3.4 : RICH hub sector 5,6
- Optical switch for MDC1/2
- Media Converters for RICH
- CTS/Start/Veto (height: 6 12 12 12)
- Lvl1 : Ethernet switch, 48V distribution, Trigger distribution
- Lvl2 : Central hub with slow control TRB
- Lvl3 : CTS board
- Lvl4 : Start/Veto TRB
- On each TOF sector (height: 12), 7 stacks in total
48V power supply
In total 5 48V power supplies will be used:
- 2 for RPC (in old Shower rack)
- 1 for RICH frontends (in MDC LV rack)
- 1 for RPC, FW & Shower TRBs incl. hubs (in old Shower rack)
- 1 for all other TRBs (in MDC LV rack)
All 3 RPC/Shower power supplies can be installed in a rack next to the rear part. The other 2 in the rack with MDC power supplies.
Detector |
Current |
RPC |
60A (detector) + 20A (TRB) |
Shower |
5A |
TOF |
10A |
RICH |
25A |
MDC |
5A |
Hubs |
8A |
Others |
8A |
--
JanMichel - 26 Jan 2010