Summary Table: new boards (assembled in 2011)

  • Tested in July 2014 by C.Wendisch & Kathrin Bismark (Sommerstudent)
  • calibration files md14...hld (if available,files earlier < md14140 were deleted and not archived ) located at lxhadeb06://home/mdc/offline/data
%GENPDF%
Serial ID Short(1)/Long(2) Comment Test: Noise Data and Thresholds Test: Calibration Calibration File threshold pulser DataRate (noise)
N106
1
 
OK
OK
md1413917145402.hld
0x20
5 kHz
88000 Hz
MB0429
2
Calibration time difference differs for channel >80
OK
OK
md1421113001302.hld
0x20
1 kHz
2 kHz
N09
2
Calibration time difference differs for channel >70
OK
OK
md1421113292202.hld
0x20
1 kHz
2150 Hz
N205
2
Missing Tokens:110; Calibration time difference differs for channel >85
OK
OK
md1421113514702.hld
0x20
1 kHz
2500 Hz
N207
2
Missing Tokens: 2; Calibration time difference differs for channel >70
OK
OK
md1421114124502.hld
0x20
1 kHz
2050 Hz
MB0502
2
 
OK
OK
md1421114260402.hld
0x20
1 kHz
2600 Hz
MB0500
2
 
OK
OK
md1421114400802.hld
0x20
1 kHz
2800 Hz
MB0435
2
Calibration time difference differs for channel >90
OK
OK
md1421114510502.hld
0x20
1 kHz
2400 Hz
MB0516
2
 
OK
OK
md1421115014202.hld
0x20
1 kHz
1900 Hz
MB0507
2
no calibration data
OK
failed
md1421116415202.hld
0x20
1 kHz
40000 Hz
MD0433
2
wrong calibration in channels 65-75
OK
failed
md1421115374702.hld
0x20
1 kHz
2350000 Hz
MB0439
2
FEE Error
 
 
 
 
 
 
N204
2
wrong calibration
OK
failed
md1421210204502.hld
0x20
1 kHz
200 Hz
N206
2
Missing Tokens: 7; Calibration time difference differs for channel >60
OK
OK
md1421210303702.hld
0x20
1 kHz
2600 Hz
N17
2
Calibration time difference differs for channel >70
OK
OK
md1421210451302.hld
0x20
1 kHz
2400 Hz
N18
2
Calibration time difference differs for channel >70
OK
OK
md1421210534002.hld
0x20
1 kHz
1950 Hz
N201
2
Missing Tokens: 6; Calibration time difference differs for channel >80
OK
OK
md1421211065202.hld
0x20
1 kHz
2750 Hz
N203
2
Missing Tokens: 9; Calibration time difference differs for channel >70 and calibration time off set for channels 24-32
OK
OK
md1421211144802.hld
0x20
1 kHz
3250 Hz
N10
2
Missing Tokens: 5; Calibration time off set for channels 76-80; Calibration time difference differs for channel >85
OK
OK
md1421211223402.hld
0x20
1 kHz
2500 Hz
N209
2
 
OK
OK
md1421211302302.hld
0x20
1 kHz
2200 Hz
MB0430
2
Missing Tokens: 6; Calibration time off set for channels 36-42 and 44-47;
OK
OK
md1421211372802.hld
0x20
1 kHz
3250 Hz
N208
2
almost no reaction on threshold changes; wrong calibration in channels 7-16; Calibration time difference differs for channels 9-16
failed
failed
md1421211503502.hld
0x20
1 kHz
111000 Hz
N202
2
Missing Tokens: 8; Calibration time difference differs for channel >80
OK
OK
md1421211594202.hld
0x20
1 kHz
1950 Hz
N12
2
 
 
 
md1413510190302.hld
0x40
5 kHz
 
N13
2
4 Missing Tokens
 
 
md1413510283102.hld
0x40
5 kHz
2400 Hz
N001
2
 
 
 
md1413419043802.hld
0x40
5 kHz
 
N101
1
 
OK
 
md1413510535602.hld
0x40
5 kHz
500 Hz
MB0120
1
 
OK
 
md1413610185802.hld
0x40
5 kHz
2400 Hz
MB0267
1
 
OK
 
md1413911594702.hld
0x30
5 kHz
5000 Hz
MB0130
1
channel 38,39 calibration time2 = 2000
OK
 
md1413912321102.hld
0x20
5 kHz
84000 Hz
MB0076
1
FEE Error
failed
failed
 
0x40
 
 
OLD001
1
No Data
failed
failed
 
0x10
 
 
MB0290
1
 
OK
 
md1413913293302.hld
0x20
5 kHz
78000 Hz
N102
1
 
 
 
md1413914032502.hld
0x20
5 kHz
86000 Hz
N103
1
 
 
 
md1413914203802.hld
0x20
5 kHz
84000 Hz
N104
1
 
 
 
md1413914464202.hld
0x20
5 kHz
86000 Hz
MB0218
1
 
 
 
md1413915000802.hld
0x20
5 kHz
70000 Hz
N105
1
now mounted in HADES address 0x2124
 
 
md1413915173202.hld
0x20
5 kHz
87000 Hz
N106
1
 
 
 
md1413917145402.hld
0x20
5 kHz
88000 Hz
MB0034
1
FEE Error
failed
 
 
0x20
5 kHz
 
N107
1
No Data
failed
 
 
 
 
 
N108
1
No Data
failed
 
 
 
 
 
N19
1
 
 
 
md1413919215302.hld
0x20
5 kHz
60000 Hz
N109
1
NO calibration channel 8-15, bad channel 24-31
 
 
md1413919215302.hld
0x20
5 kHz
60000 Hz
N01
1
 
 
 
md1413919382402.hld
0x20
5 kHz
60000 Hz
N07
1
 
 
 
md1413919451902.hld
0x20
5 kHz
61000 Hz
N06
1
 
 
 
md1413920090602.hld
0x10
5 kHz
255000 Hz
 
 
 
 
 
 
 
 
 

Summary Table: old boards

Serial ID
Short(1)/Long(2)
Identified Problem
Test: Noise Data and Thresholds
Test: Calibration
Action
Status
Notes
 
0516
2
ABTH18502 or CPLD
OK
not OK
CPLD reprogrammed
OK
 
 
0433
2
ABTH18502 or CPLD
OK
not OK
CPLD reprogrammed
OK
 
 
0411
2
token chain
not OK
not OK
CPLD reprogrammed
not OK
no token out of CPLD
 
0503
2
token chain
 
 
Gabi improved soldering
not OK
 
 
0529
2
 
OK
OK
 
OK
 
 
0485
2
 
OK
OK
 
OK
 
 
0436
2
 
OK
OK
 
OK
 
 
0497
2
token chain
 
 
Gabi improved soldering
not OK
 
 
0507
2
 
 
no ch1 in each TDC
 
 
 
 
0557
2
 
OK
OK
 
OK
 
 
0512
2
 
OK
OK
 
OK
 
 
O439
2
 
 
not OK
CPLD reprogrammed
not OK
no token out of CPLD
 
0542
2
 
OK
OK
 
OK
 
 
NO NUMBER
2
 
OK
OK
 
OK
 
 
0449
2
 
OK
OK
 
OK
 
 
0501
2
 
 
not OK
 
 
 
 
0044
1
 
 
not OK
CPLD reprogrammed
not OK
no token out of CPLD
 
0167
1
 
OK
OK
 
OK
 
 
0266
1
 
OK
OK
 
OK
 
 
0078
1
dead
 
 
CPLD reprogrammed
not OK
no token out of CPLD
 
0033
1
 
OK
OK
 
OK
 
 
0187
1
dead
 
 
CPLD reprogrammed
not OK
no token out of CPLD
 
0068
1
 
OK
OK
 
OK
 
 
0102
1
 
OK
OK
 
OK
 
 
0290
1
 
OK
OK
 
OK
 
 
0023
1
 
 
not OK
CPLD reprogrammed
not OK
 
 
0159
1
 
OK
OK
 
OK
 
 
0267
1
 
OK
OK
 
OK
 
 
0142
1
no TDC3 in calibration
 
 
 
 
 
 
0201
1
 
 
not OK
 
 
 
 
0208
1
 
OK
OK
 
OK
 
 
0169
1
 
 
no TDC1,3,5,7 in cal.
CPLD reprogrammed
not OK
no TDC1,3,5,7 in cal.
 
0193
1
 
no TDC5-8 in data
OK
OP3 exchanged
not OK
check DAC
 
0280
1
 
 
not OK
CPLD reprogrammed
not OK
short token out of TDC1
 
0040
1
dead
 
 
CPLD reprogrammed
not OK
no token out of CPLD
 
0133
1
 
OK
OK
 
OK
 
 
0104
1
dead
 
 
CPLD reprogrammed
OK
 
 
0061
1
 
TDC5-7 threshold problem (?)
OK
OP3 exchanged
OK
 
 
0106
1
 
 
only TDC8 in cal.
CPLD reprogrammed
OK
 
 
0072
1
 
 
not OK
 
 
 
 
0430
2
smoke
not tested
not tested
3 opamps exchanged
OK
 
 

Summary Table: new boards (assembled in 2011)

Serial ID
Short(1)/Long(2)
 
Test: Noise Data and Thresholds
Test: Calibration
Note
Location
 
 
N01
1
 
OK
OK
 
 
 
 
N02
1
 
OK
OK
 
 
 
 
N03
1
 
OK
OK
 
 
 
 
N04
1
 
OK
OK
 
 
 
 
N05
1
 
OK
OK
 
 
 
 
N06
1
 
OK
OK
 
 
 
 
N07
2
 
OK
OK
 
 
 
 
N08
2
 
OK
OK
 
 
 
 
N09
2
 
OK
OK
 
 
 
 
N10
2
 
OK
OK
 
 
 
 
N11
2
 
OK
OK
 
 
 
 
N12
2
 
OK
OK
 
 
 
 
N13
2
 
OK
OK
 
 
 
 
N14
2
 
OK
OK
 
 
 
 
N15
2
 
 
not OK
 
 
 
 
N16
2
 
 
not OK
still not OK after reprogramming CPLD
 
 
 
N17
2
 
OK
OK
 
 
 
 
N18
2
 
OK
OK
 
 
 
 
N19
1
 
OK
OK
OK after reprogramming CPLD
 
 
 

Summary of boards debugged between 28.03.2011 and 01.04.2011

60 tested;

41 correctly operating boards boards after debugging (including 7 fixed)

Correctly operating boards: 11 old long, 13 old short, 10 new long, 7 new short

Tests were based on noise, no input signal provided.

Summary Table: board exchanged in the detectors between 01.03.2011 and 01.05.2011

Serial ID
Short(1)/Long(2)
Plane and Sector (count from 0)
Position on Sector
Problem observed
Exchanged with MB
*
 
 
0068
1
9
TDCs missing
0195
 
 
 
0142
1
8
TDCs missing
0172
 
 
 
0159
1
3
TDCs missing
0002
 
 
 
0167
1
4
TDCs missing
0283
 
 
 
0475
2
E
TDCs missing in calibration
557
 
 
 
 
 
 
 
 
 
 
 
 

-- AttilioTarantola - 29 Mar 2011

Temperature Test for the Mother Boards

MB ID Result
0068
OK
0159
OK
0167
OK
N 01
OK
N 02
OK

-- CahitUgur - 05 Apr 2011
Topic revision: r25 - 2014-10-13, ChristianWendisch
Copyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki Send feedback | Imprint | Privacy Policy (in German)