Here a list of all taken hld-files should be maintained. All files are to be recorded in: hadaq@lxhadeb01:/data01/data

MDC III Sector 0

MDC III Sector 1

MDC III Sector 2

threshold pulser calibration file name # events power consumption temperature
0x20
 
 
 
 
 
 
0x30
 
 
 
 
 
 
0x38
 
on
te1105415584201
 
 
 
0x40
 
on
te1104815190501 te1105416232201
 
 
 
0x50
 
on
te1104816403201 te1105416351101 te1105416581201
 
 
 
0x60
 
on
te1104816470901
 
 
 
0xff
 
on
te1104816515201
 
 
 
0xa0
 
 
 
 
 
 
0xf0
 
 
 
 
 
 
0x70
 
 
 
 
 
 

Comments: We saw that MB 2218 behaved in a strange way due to a trigger cable broken. It didn't delivered both real both calibration data. The floating timing trigger signal induced in the TDCs during the calibration corrupted the calibration and no data was delivered by the TDC. Therefore we changed the trigger cable.

MDC III Sector 3

MDC III Sector 4

MDC III Sector 5

test of MDC III performed day: 29.03.2011

We have collected only calibration events, by setting: trigger type 9 on and pulser 10Hz.
Threshold has been set to 40 for all planes.
The following pictures are showing typical patterns (MBO vs. TDC) for MDC III.

In this plot we only get a entry in case that TDC delivered 6 data words.

We can see some kind of pattern, which is repeated in all sectors, where some of the TDCs do not
deliver all 6 data words. This should be check if this is correct.

In sector 3 and 5, the motherboard 8 is only missing after a power cycle!

MIssing staff in sector 3: MBO 8 and also few TDC in MBO4 were already observed on Friday.

Some TDC are completely missing in all 6 sectors

mdc III cal
Topic revision: r6 - 2011-03-29, GosiaSudol
Copyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.