I have made new event mixing for the full target with and without HV problems.
Analysis are done with the
new SHOWER cut.
In all plots, once openign angle, pt or rapidity are represented cut on the M >0.15GeV/c2 is applied.
All lepton cuts have been applied.
For the RAW plotting following cut have been chosen:
cut7:
kStandardAnalysisCutsNOV02 = kAllPairCutsPassed && kNoLegIsClosePairCandidate && kIsUpperMomentum2GeV
cut10:
cut7 && kHigherThanPionMass
For the efficiency correction following cut has been applied:
cut20:
kStandardAnalysisCutsNOV02 = kAllPairCutsPassed && kNoLegIsClosePairCandidate && kIsUpperMomentum2GeV
cut23:
cut7 && kHigherThanPionMass
Normalizattion:
|
range |
Mee |
0.15 -0.4 GeV/c2 |
Pt |
0.04 - 0.6 GeV/c |
Y |
0.1 - 1.9 |
Op |
20 - 120 degree |
buffor size - 100.
In attachment i have added macro which i was using for plotting, as well for analysis of event mixing.
What is important here is the fact that i was using my local pair module /misc/sudol/hydra/v8_11, where are some fixes
to be able to run event mixing. I need to talk with Jacek about this.
full target with good HV
full target with good HV, efficiency corrected
full target with bad HV
full target with good and bad HV
full target with good and bad HV, efficiency corrected
full target with good HV, runge kutta
full target with good and bad HV, runge kutta
--
GosiaSudol - 04 Apr 2007