contains all information about the mdc parameters for the 1st Aug04Sim DST production

Mdc Setup



Mdc Digitizer

signal speed not changed --> signalspeed: f 0.004

layer efficiencies changed:
(sector*24)+(module*6)+layer
s=0, m=0 -> layer=0,1,2,3,4,5
s=0, m=1 -> layer=6,7,8,9,10,11
..
s=0, m=3 -> layer=18,19,20,21,22,23
s=1, m=0 -> layer=24,25,26,...
thus the order is like this
I1 all layers, II1 all layers, III1 all layers, IV all layers
I2 all layers, ....

efficiency information used:


written to oracle:
layEff:  f \
  1.000, 0.900, 0.800, 1.000, 0.900, 0.900, 0.900, 1.000, 1.000, 1.000, \
1.000, 0.900, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 0.000, 0.000, \
0.800, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, \
1.000, 0.800, 1.000, 0.800, 1.000, 0.800, 1.000, 1.000, 1.000, 1.000, \
1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, \
1.000, 1.000, 1.000, 0.800, 1.000, 1.000, 1.000, 0.900, 1.000, 1.000, \
1.000, 1.000, 1.000, 1.000, 0.700, 0.000, 1.000, 1.000, 1.000, 1.000, \
1.000, 1.000, 1.000, 1.000, 1.000, 0.900, 0.900, 1.000, 1.000, 1.000, \
1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, \
1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, \
0.200, 1.000, 1.000, 1.000, 0.900, 1.000, 1.000, 1.000, 1.000, 1.000, \
1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, \
1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, \
1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, 1.000, \
1.000, 1.000, 1.000, 1.000
signalspeed: f 0.004

MdcCal2ParSim

version 331 validated for projects 7000-7003

description:
GARFIELD, HV=1750,1800,2000,2200, threshold 10 %, slope 10 , cut at 110,120,260,370 , smoothed calibrat ion parameters for CAL2

comment: no other parameters available


MdcCellEffProduction

version 332 validated for projects 7000-7003

description:
GARFIELD, HV=1750,1800,2000,2200, threshold 10 %, slope 10 , cut at 110,120,260,370 , smoothed Cut valu es for Digitizer for cell efficiency

comment: no other parameters available


WireStat Container

aug04 mdc wire status according to calparraw container, bitflip mbos additionally set to status -3 (==wire connected and dead), only simulation

version 333


-- YvonnePachmayer - 14 Aug 2005

I Attachment Action Size Date Who Comment
aug04mdcsetupsimulmagnetic.txttxt aug04mdcsetupsimulmagnetic.txt manage 1 K 2005-08-31 - 19:48 YvonnePachmayer mdcsetup, magnetic field on, simulation
aug04mdcsetupsimulnomagnetic.txttxt aug04mdcsetupsimulnomagnetic.txt manage 1 K 2005-08-31 - 19:48 YvonnePachmayer mdc setup, no magnetic, simulation
Topic revision: r3 - 2005-08-31, YvonnePachmayer
Copyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki Send feedback | Imprint | Privacy Policy (in German)