QA Go4
Color and coditions in efficiency plot:
- Red: Start IF ( VetoXR && VetoXL && VetoYR && VetoYL )
- Blue: Start IF ( VetoXR || VetoXL || VetoYR || VetoYL )
- Magenta: VetoYR IF ( Start && ( VetoXR || VetoXL ))
- DarkGreen: VetoYL IF ( Start && ( VetoXR || VetoXL ))
- GreyBlue: VetoXR IF ( Start && ( VetoYR || VetoYL ))
- DarkRed: VetoXL IF ( Start && ( VetoYR || VetoYL ))
- LightGreen: ( VetoXR || VetoXL ) IF ( Start && VetoYR && VetoYL )
- Yellow: ( VetoYR || VetoYL ) IF ( Start && VetoXR && VetoXL )
(X,Y,L,R have to be checked!!!)
In the Veto Sport picture, U/D and L/R are exchanged (
VetoX<->VetoY), i will change that later.
HV
- HV is using Pion HV, Card 11-14 (Epics numbering)
- HV is set to -1400V
- Channel 175 is broken -> 0V
- Card 11 is VetoY Chn...? Order reversed?
- Card 12 is VetoY Chn...? Order reversed?
- Card 13 is VetoX Chn...? Order reversed?
- Card 14 is VetoX Chn...? Order reversed?
Leding Edges
- using FW, LE 0-3
- correspond to top to bottom order in mini VME crate
- 0, 1 is VetoX
- 2, 3 is VetoY
VetoX
- Hodo2 is Mod 2 (and 4), running Left to Righ in beam direction
- channels 0-31
- chn31 missing in mod 4 (time ref)
VetoY
- Hodo3 is Mod 3 (and 5), running Bottom to Top (?)
- channels 0-31
- chn0 missing in mod 3 (no HV)
- chn31 missing in mod 5 (time ref)
Start
- Start is Mod 1
- channel 0-7
Status
- Veto Scalers are checked and O.K. (LRUD)
- To be checked in Data/Go4, there UDLR might be wrong
--
BjoernSpruck - 16 Sep 2008