QA Go4

Color and coditions in efficiency plot:

  • Red: Start IF ( VetoXR && VetoXL && VetoYR && VetoYL )
  • Blue: Start IF ( VetoXR || VetoXL || VetoYR || VetoYL )
  • Magenta: VetoYR IF ( Start && ( VetoXR || VetoXL ))
  • DarkGreen: VetoYL IF ( Start && ( VetoXR || VetoXL ))
  • GreyBlue: VetoXR IF ( Start && ( VetoYR || VetoYL ))
  • DarkRed: VetoXL IF ( Start && ( VetoYR || VetoYL ))
  • LightGreen: ( VetoXR || VetoXL ) IF ( Start && VetoYR && VetoYL )
  • Yellow: ( VetoYR || VetoYL ) IF ( Start && VetoXR && VetoXL )

(X,Y,L,R have to be checked!!!)

In the Veto Sport picture, U/D and L/R are exchanged (VetoX<->VetoY), i will change that later.

HV

  • HV is using Pion HV, Card 11-14 (Epics numbering)
  • HV is set to -1400V
  • Channel 175 is broken -> 0V
  • Card 11 is VetoY Chn...? Order reversed?
  • Card 12 is VetoY Chn...? Order reversed?
  • Card 13 is VetoX Chn...? Order reversed?
  • Card 14 is VetoX Chn...? Order reversed?

Leding Edges

  • using FW, LE 0-3
  • correspond to top to bottom order in mini VME crate
  • 0, 1 is VetoX
  • 2, 3 is VetoY

VetoX

  • Hodo2 is Mod 2 (and 4), running Left to Righ in beam direction
  • channels 0-31
  • chn31 missing in mod 4 (time ref)

VetoY

  • Hodo3 is Mod 3 (and 5), running Bottom to Top (?)
  • channels 0-31
  • chn0 missing in mod 3 (no HV)
  • chn31 missing in mod 5 (time ref)

Start

  • Start is Mod 1
  • channel 0-7

Status

  • Veto Scalers are checked and O.K. (LRUD)
  • To be checked in Data/Go4, there UDLR might be wrong

-- BjoernSpruck - 16 Sep 2008