Where to find QA check list file

Here:
  • for August 2011: /u/hades-qa/Desktop/QA Check List - Aug11/QA_check_list_Au_Au_aug2011.pdf (see also attachement)

Where to get informations for check list

Magnet
If major problems appear, call:
  • Wolfgang Knig: 0172/8775049
  • Torsten Heinz: 0175/3884066
  • Go to Magnet Control Computer in the second floor above the HADES experiment and check computer screen for:
Magnet.png

START/VETO
  • Go to DAQ monitors
    • Read values from Start Display (window not labeled, but the diamond-shaped Start detector is clearly identifiable)
    • Take values from RIGHT column, not the left one as shown in the picture.
Start.png

RICH
  • Check Pad mult./evt in the corresponding RICH online monitoring pictures
  • Open epics window
    • Click on "rich" button
    • Click on "Rich HV" button
    • Click on "HV Control" button

Rich_HV_Settings.png

  • Go to the RICH rack in front of the lower counting house

Rich_rack.png

MDC
  • MDC
    • "HV settings changed", "Thresholds changed" -> ask experts
    • "ERROR-BITS" -> check in QA plots (MDC panel, ErrStat tab)
    • "Gas bubbler" -> see picture below
    • "Interlocks enabled"
    • "Gas - System", "Temperature" ???
  • MDC Gas-System readings
    • Go to the MDC rack in front of counting house

MDC_Rack.png

    • Open epics window ( NOT NEEDED ANYMORE FOR 2012 BEAMTIME, BUT ASK MDC EXPERT TO CHECK THE PRESSURES )
    • Click on "MDC" button
    • Click on "Mdc gaspressure"

MDC_Gas_Pressure.png

TOF

  • Check in your QA plots
  • "TOF counts/s " -> check CTS window -> See the six TOF sectors -> Check for scalers during a spill -> estimate average

cts.png

RPC
  • Open epics window
    • Click on "RPC" button
    • Click on "Gas System" button
    • Check values:
RPC_Gas_System.png

  • Open epics window
    • Click on "MDC" button
    • Click on "MDC gas scales" button
MdcGasScale.png

  • Go to the RPC rack in front of the lower counting house
RPCRack.png

  • Check "Currents in SC"
    • Open epics window
    • Click on "RPC" button
    • Click on "HV" button
    • Click on "Monitor (1ua)" button
    • 6 different colored histograms appear in two windows -> If the six histograms are more or less the same -> ok!

SHOWER
  • Go to the balance near the stairs to upper counting house
Waage.png
  • Go to SHOWER rack in front of lower counting house
SHOWER_Rack.png
  • open epics window
    • Click on "shower" button
    • Click on "SHWR HV" button
    • Click on "ALL SECTOR" button
showerepics.png
Forward Wall
  • Check your QA plots
HADES VACUUM
  • Open epics window
    • Click on "misc." button
miscepics.png
ICINGA
  • ???
Online Vertex
  • Go to lower monitors on QA operator place
    • Click "Open VertexMon" button
    • Click "Start VRC Server.deskt op" button -> Vetrex Reconstruction pictures pop up
Slow Control (Archiver)
To check if the file archiver is running go to http://lxg0434:4812

-- RafalLalik - 10 Aug 2011

Topic revision: r10 - 2012-03-30, JohannesSiebenson
Copyright © by the contributing authors. All material on this collaboration platform is the property of the contributing authors.
Ideas, requests, problems regarding Foswiki Send feedback | Imprint | Privacy Policy (in German)