GENERAL DESCRIPTION:
Each fault input can be independently configured by an individual personality module via jumpers and resistors.
A programmable time constant determines how long a fault input error condition must be present before it trips the fault latch. The fault latch delay time constant can be set from 250 µs to 105 s. Any fault trip drives the Daisy-Chain output. Systems requiring more than eight fault inputs can be accommodated by concatenating two or more SIAMs via front panel LEMO Daisy-Chain input and Daisy-Chain output connectors. The Daisy Chain input is TTL compatible and the Daisy Chain output is a TTL open-collector output.
I | Attachment | Action | Size | Date | Who | Comment |
---|---|---|---|---|---|---|
![]() |
HVcurrmon_description.pdf | manage | 9.7 K | 05 Oct 2012 - 11:42 | PeterZumbruch | HV current monitor description |
![]() |
c166ism.pdf | manage | 1179.5 K | 09 Oct 2012 - 16:03 | PeterZumbruch | c166 series instruction set manual |
![]() |
c167cr_ds.pdf | manage | 965.2 K | 09 Oct 2012 - 09:29 | PeterZumbruch | C167CR Data Sheet |
![]() |
c167cr_um.pdf | manage | 3817.6 K | 09 Oct 2012 - 16:04 | PeterZumbruch | c167CR User Manual |
![]() |
cwallner.pdf | manage | 1259.4 K | 05 Oct 2012 - 11:33 | PeterZumbruch | Ein rechnergestütztes Steuer- und Kontrollsystem für den HADES-RICH, Diplomarbeit von Christian Wallner Fakultät f¨ur Physik der Technischen Universität München Physik-Department E12 Dezember |
![]() |
d167r16f.pdf | manage | 860.4 K | 09 Oct 2012 - 16:05 | PeterZumbruch | C167CR_16FM Data Sheet |
![]() |
hvamp.pdf | manage | 72.6 K | 05 Oct 2012 - 11:41 | PeterZumbruch | schematics HV amplifier |
![]() |
jb99_p94.pdf | manage | 218.0 K | 05 Oct 2012 - 11:27 | PeterZumbruch | A Slow Control System for the HADES RICH |